One-phase Automatic Voltage Regulator
The largest selling and trusted regulator brand of Viet Nam, Hansinco, offers the best technology. With features like automatic restart, turn-on delay, time-delay system and high & low voltage cut-off that provide efficient and reliable protection for electronic appliances against voltage problems.
Hansinco Regulators come in different capacities for different applications like Air Conditioner, LCD TV, Music System, Refrigerator, Deep Freezer, Washing Machine, Microwave Oven, Treadmill and Mainline Stabilizers for general purposes.
Hansinco provides a lot of variation in the voltage regulator range so that you find a perfect fit for your appliance. You can browse across the category to find a suitable one for your precious appliances.
- 15 second circuit delay at initial start
- Automatic power-off at high voltage
- Circuit line protection
- Anti-voltage protection and auto reset
* These features are to protect your equipment during power failures.
General information |
Place of Origin |
Ho Chi Minh, Vietnam |
Material Original Countries |
Copper winding wire: Made in Vietnam (Japanese brand) Tole Silic: Made in Vietnam (Usa and Japanese brand) |
|
Input |
Input Voltage |
40V-240V, 60V-240V, 90V-240V, 140V-240V, 50V-250V, 90V-250V, 150V-250V, 170V-270V |
Input frequency |
Plus or minus ±15%~±60% |
|
Output |
Output Voltage |
220V & 110V
|
Output Voltage accuracy |
±3% |
|
Protection |
Protection over voltage |
<250±2V Output phase voltage 10%, cut-off input or transfer to bypass |
Over Loading protection |
more than 120% Electronic detection, cut off input in one minute |
|
Bypass protection |
Automatically transfer to bypass in case of failure |
|
Phase lack protection |
Cut-off automatically |
|
Other specification |
Phase |
Three-phase |
Power factor |
0.8 |
|
Efficiency |
≥98% |
|
Response time |
≤0.03s |
|
Response speed |
4V~6V/sec |
|
Ambient Temperature |
-5°C~50°C |
|
Relative Humidity |
<80% |
|
Insulating Resistance |
3-100 MΩ/ DC-500V |
|
Waveform |
Sin Wave (no additional waveform distortion) |
|
Current Type |
AC |
|
Frequency |
50/60HZ |
|
Technology |
Servo Motor Control |
|
Display |
Analog Meter |
|
Winding |
100% copper |
|
Over Temperature |
120°C±10°C |
|
Delay time |
6s/300s selectable |
|
Noise |
Less than 45dB (1m distance) |
|
Cooling system |
Cooling fan |
|
Certificate |
ISO9001:2008 |
|
Number of slot |
1 |
Spec(KVA) | Product size DxWxH(cm) | Package size DxWxH(cm) | Product weight (kg) | Package weight (kg) | Quantity | Input Range | Item Code |
---|---|---|---|---|---|---|---|
750 VA | 17x23x17.5 | 40.5x25.5x39 | 5.5 | 22 | 4 | 140V-240V | S1P750V140-R H |
1 KVA | 19.5x27.5x23.5 | 41x29x48 | 8 | 32 | 4 | 140-240V | S1P1K140-R |
90-240V | S1P1K90-R | ||||||
60-240V | S1P1K60-R | ||||||
50-250V | S1P1K50-S | ||||||
90-250V | S1P1K90-S | ||||||
1.5 KVA | 19.5x27.5x23.5 | 41x29x48 | 8.5 | 34 | 4 | 140-240V | S1P1.5K140-R |
90-240V | S1P1.5K90-R | ||||||
60-240V | S1P1.5K60-R | ||||||
40-240V | S1P1.5K40-R | ||||||
2 KVA | 21.5x31x25 | 44x33x52 | 11.5 | 46 | 4 | 140-240V | S1P2K140-R |
90-240V | S1P2K90-R | ||||||
60-240V | S1P2K60-R | ||||||
40-240V | S1P2K90-S | ||||||
50-250V | S1P2K40-R | ||||||
3 KVA | 24.5x34x32 | 51x36x33 | 15 | 30 | 2 | 140-240V | S1P3K140-R |
90-240V | S1P3K90-R | ||||||
60-240V | S1P3K60-R | ||||||
40-240V | S1P3K40-R | ||||||
50-250V | S1P3K50-S | ||||||
4 KVA | 26.5x37x35 | 54x38x36 | 17 | 34 | 2 | 140-240V | S1P4K140-R |
90-240V | S1P4K90-R | ||||||
60-240V | S1P4K60-R | ||||||
40-240V | S1P4K40-R | ||||||
50-250V | S1P4K50-S | ||||||
5 KVA | 26.5x37x35 | 54x38x36 | 18.5 | 37 | 2 | 140-240V | S1P5K40-R |
S1P5K140-R | 90-240V | ||||||
S1P5K90-R | 60-240V | ||||||
S1P5K140-R | 40-240V | ||||||
S1P5K140-R | 50-250V | ||||||
S1P5K50-S | 50-250V | ||||||
6 KVA | 26.5x37x35 | 54x38x36 | 19 | 38 | 2 | 140-240V | S1P6K140-R |
90-240V | S1P6K90-R | ||||||
60-240V | S1P6K60-R | ||||||
40-240V | S1P6K40-R | ||||||
7 KVA | 26.5x37x35 | 54x38x36 | 21 | 42 | 2 | 140-240V | S1P7K140-R |
90-240V | S1P7K90-R | ||||||
60-240V | S1P7K60-R | ||||||
40-240V | S1P7K40-R | ||||||
8 KVA | 29x44x48 | 29x44x48 | 31 | 31 | 1 | 140-240V | S1P8K140-R |
90-240V | S1P8K90-R | ||||||
60-240V | S1P8K60-R | ||||||
40-240V | S1P8K40-R | ||||||
10 KVA | 29x44x71 | 29x44x71 | 35.5 | 35.5 | 1 | 140-240V | S1P10K140-R |
90-240V | S1P10K90-R | ||||||
60-240V | S1P10K60-R | ||||||
40-240V | S1P10K40-R | ||||||
15 KVA | 41x48x71 | 41x48x71 | 53 | 53 | 1 | 140-240V | S1P15K140-R |
90-240V | S1P15K90-R | ||||||
60-240V | S1P15K60-R | ||||||
40-240V | S1P15K40-R | ||||||
50-250V | S1P15K50-S | ||||||
20 KVA | 45x56x75 | 45x56x75 | 85 | 85 | 1 | 140-240V | S1P20K140-R |
90-240V | S1P20K90-R | ||||||
60-240V | S1P20K60-R | ||||||
40-240V | S1P20K40-R | ||||||
50-250V | S1P20K50-S | ||||||
25 KVA | 47x61x83 | 47x61x83 | 89 | 89 | 1 | 140-240V | S1P25K140-R |
90-240V | S1P25K90-R | ||||||
60-240V | S1P25K60-R | ||||||
30 KVA | 47x61x83 | 47x61x83 | 100 | 100 | 1 | 140-240V | S1P30K140-R |
90-240V | S1P30K90-R | ||||||
60-240V | S1P30K60-R | ||||||
90-250V | S1P30K90-S | ||||||
40 KVA | 47x61x83 | 47x61x83 | 116 | 116 | 1 | 140-240V | S1P40K140-R |
90-240V | S1P40K90-R | ||||||
60-240V | S1P40K60-R | ||||||
50 KVA | 49x66x117 | 49x66x117 | 140 | 140 | 1 | 140-240V | S1P50K140-R |
90-240V | S1P50K90-R | ||||||
60-240V | S1P50K60-R | ||||||
60 KVA | 49x66x117 | 49x66x117 | 180 | 180 | 1 | 140-240V | S1P60K140-R |
90-240V | S1P60K90-R | ||||||
60-240V | S1P60K60-R | ||||||
80 KVA | 84x48x136 | 84x48x136 | 200 | 200 | 1 | 140-240V | S1P80K140-R |
90-240V | S1P80K90-R | ||||||
60-240V | S1P80K60-R | ||||||
100 KVA | 73x99x130 | 73x99x130 | 230 | 230 | 1 | 140-240V | S1P100K140-R |
90-240V | S1P100K90-R | ||||||
60-240V | S1P1000K60-R | ||||||
120 KVA | 73x99x130 | 73x99x130 | 320 | 320 | 1 | 140-240V | S1P120K140-R |
90-240V | S1P120K90-R | ||||||
60-240V | S1P120K60-R |